Publications

Export 28 results:
Filters: Keyword is Imaging  [Clear All Filters]
2007
Krieger, A., Csoma C., Iordachita I., Guion P., Singh A. K., Fichtinger G., et al. (2007).  Design and preliminary accuracy studies of an MRI-guided transrectal prostate intervention system. Medical image computing and computer-assisted intervention (MICCAI). 10, 59–67.PDF icon Krieger2007a.pdf (1.41 MB)
Kazanzides, P., Chang J., Iordachita I., Li J., Ling C., & Fichtinger G. (2007).  Development of an image-guided robot for small animal research. Journal of Computer Aided Surgery. 12, 357–365.PDF icon Kazanzides2007.pdf (816.37 KB)
DiMaio, S., Samset E., Fischer G., Iordachita I., Fichtinger G., Jolesz F., et al. (2007).  Dynamic MRI scan plane control for passive tracking of instruments and devices. Medical image computing and computer-assisted intervention (MICCAI). 10, 50–58.PDF icon DiMaio2007.pdf (3.16 MB)
Jain, A. K., Degeut A., Iordachita I., Chintalapani G., Blevins J., Yi L., et al. (2007).  Intra-operative 3D guidance in prostate brachytherapy using a non-isocentric C-arm. Medical image computing and computer-assisted intervention (MICCAI). 10, 9–17.PDF icon Jain2007.pdf (3.49 MB)
Liu, X., Jain A. K., & Fichtinger G. (2007).  Prostate implant reconstruction with discrete tomography. Medical image computing and computer-assisted intervention (MICCAI). 10, 734–742.PDF icon Liu2007.pdf (615.02 KB)
Krupa, A., Fichtinger G., & Hager G. D. (2007).  Real-time tissue tracking with B-mode ultrasound using speckle and visual servoing. Tenth International Conference on Medical Image Computing and Computer-Assisted Intervention (MICCAI). 10, 1–8.PDF icon Krupa2007.pdf (5.31 MB)
Labat, C., Jain A. K., Fichtinger G., & Prince J. L. (2007).  Toward optimal matching for 3D reconstruction of brachytherapy seeds. Medical image computing and computer-assisted intervention (MICCAI). 10, 701–709.PDF icon Labat2007.pdf (377.32 KB)
Blumenfeld, P., Hata N., DiMaio S., Zou K., Haker S., Fichtinger G., et al. (2007).  Transperineal prostate biopsy under magnetic resonance image guidance: a needle placement accuracy study. Journal of magnetic resonance imaging. 26, 688–694.PDF icon Blumenfeld2007.pdf (393.43 KB)
2006
Boctor, E., Iordachita I., Choti M., Hager G. D., & Fichtinger G. (2006).  Bootstrapped ultrasound calibration. Studies in health technology and informatics. 119, 61–66.
Jain, A. K., & Fichtinger G. (2006).  C-arm tracking and reconstruction without an external tracker. Medical image computing and computer-assisted intervention (MICCAI). 9, 494–502.PDF icon Jain2006a.pdf (1.12 MB)
Kazanzides, P., Chang J., Iordachita I., Li J., Ling C., & Fichtinger G. (2006).  Design, validation of an image-guided robot for small animal research. Medical image computing and computer-assisted intervention (MICCAI). 9, 50–57.PDF icon Kazanzides2006.pdf (1.24 MB)
Xu, S., Taylor R. H., Fichtinger G., & Cleary K. (2006).  Lung deformation estimation and four-dimensional CT lung reconstruction. Journal of Academic Radiology. 13, 1082–1092.PDF icon Xu2006a.pdf (808.23 KB)
Boctor, E., de Oliveira M., Choti M., Ghanem R., Taylor R. H., Hager G. D., et al. (2006).  Ultrasound monitoring of tissue ablation via deformation model and shape priors. Medical image computing and computer-assisted intervention (MICCAI). 9, 405–412.PDF icon Boctor2006b.pdf (6.61 MB)
2005
Jain, A. K., Kon R., Zhou Y., & Fichtinger G. (2005).  C-arm calibration-is it really necessary?. Medical image computing and computer-assisted intervention (MICCAI). 8, 639–646.PDF icon Jain2005.pdf (1.56 MB)
Krieger, A., Susil R., Menard C., Coleman J., Fichtinger G., Atalar E., et al. (2005).  Design of a novel MRI compatible manipulator for image guided prostate interventions. IEEE Transactions on Biomedical Engineering. 52, 306–313.
Jain, A. K., Mustufa T., Zhou Y., E. Burdette C., Chirikjian G., & Fichtinger G. (2005).  FTRAC. Journal of Medical Physics. 32, 3185–3198.PDF icon Jain2005a.pdf (737.95 KB)
Fichtinger, G., Degeut A., Fischer G., Iordachita I., Balogh E., Masamune K., et al. (2005).  Image overlay for CT-guided needle insertions. Journal of Computer Aided Surgery. 10, 241–255.PDF icon Fichtinger_JCAS2005.pdf (447.92 KB)
Xu, S., Taylor R. H., Fichtinger G., & Cleary K. (2005).  Lung deformation estimation and four-dimensional CT lung reconstruction. Medical image computing and computer-assisted intervention (MICCAI). 8, 312–319.PDF icon Xu2005b.pdf (540.62 KB)
Jain, A. K., Zhou Y., Mustufa T., E. Burdette C., Chirikjian G., & Fichtinger G. (2005).  Matching and reconstruction of brachytherapy seeds using the Hungarian algorithm (MARSHAL). Journal of Medical Physics. 32, 3475–3492.
Cleary, K., Watson V., Lindisch D., Taylor R. H., Fichtinger G., Xu S., et al. (2005).  Precision placement of instruments for minimally invasive procedures using a "needle driver" robot. international journal of medical robotics computer assisted surgery MRCAS. 1, 40–47.PDF icon Cleary2005.pdf (378.2 KB)