Publications

Export 613 results:
Filters: Author is Gabor Fichtinger  [Clear All Filters]
2016
Anderson, R., Lasso A., Hashtrudi-Zaad K., & Fichtinger G. (2016).  Investigation of permanent magnets in low-cost position tracking. Proc. SPIE. 97862F-97862F-9.
Harish, V., Baksh A., Ungi T., Pal R., & Fichtinger G. (2016).  A low-cost system for image-guided computer-navigated pericardiocentesis training. 30th International Congress & Exhibition on Computer Assisted Radiology and Surgery (CARS). Int J CARS (2016) 11 (Suppl 1), S112.PDF icon Harish2016b.pdf (959.69 KB)
Harish, V., Baksh A., Ungi T., Lasso A., Baum Z. M. C., Gauvin G., et al. (2016).  Measurement of electromagnetic tracking error in a navigated breast surgery setup. SPIE Medical Imaging 2016. 9786, PDF icon Harish2016a.pdf (4.07 MB)
Harish, V., Baksh A., Ungi T., Lasso A., Baum Z. M. C., Gauvin G., et al. (2016).  Monitoring electromagnetic tracking error in computer-navigated breast cancer surgery. 14th Annual Imaging Network Ontario Symposium (ImNO). PDF icon Harish2016c.pdf (1.25 MB)
Marker, D. R., U-Thainual P., Ungi T., Flammang A. J., Fichtinger G., Iordachita I., et al. (2016).  MR-guided perineural injection of the ganglion impar: technical considerations and feasibility. Skeletal Radiology.
Ungi, T., Lasso A., & Fichtinger G. (2016).  Open-source platforms for navigated image-guided interventions. Medical Image Analysis. 33, 181-6.PDF icon Ungi2016a.pdf (868.77 KB)
Baum, Z. M. C., Lasso A., Ungi T., & Fichtinger G. (2016).  Real-time self-calibration of a handheld augmented reality overlay system. 14th Annual Imaging Network Ontario Symposium (ImNO). PDF icon Baum2016b.pdf (679.99 KB)
Baum, Z. M. C., Lasso A., Ungi T., & Fichtinger G. (2016).  Real-time self-calibration of a tracked augmented reality display. SPIE Medical Imaging 2016. 9786, PDF icon Baum2016a.pdf (1.85 MB)
Gauvin, G., Ungi T., Lasso A., Walker R., Rudan J., Fichtinger G., et al. (2016).  Safety and Feasibility Study for Real-Time Electromagnetic Navigation in Breast-Conserving Surgery. Computer Assisted Radiology and Surgery, 30th International Congress. 11(Suppl. 1), S106-7.PDF icon Gauvin2016a.pdf (492.77 KB)
MacNeil, K., Wang C., Holden M., Ungi T., Fichtinger G., & Hookey L. (2016).  System for objectively evaluating colonoscopy procedural skills using motion analysis. 14th Annual Imaging Network Ontario Symposium (ImNO).
Yan, C., Tabanfar R., Kempston M., Borschneck D. P., Ungi T., & Fichtinger G. (2016).  Vertebral landmark visualization with portable ultrasound imaging in scoliosis monitoring. 14th Annual Imaging Network Ontario Symposium (ImNO). PDF icon Yan2016b.pdf (388.09 KB)
Carter, K., Vaughan T., Holden M., Gauvin G., Pezeshki P., Lasso A., et al. (2016).  Visual feedback mounted on surgical tool: proof of concept. SPIE Medical Imaging 2016. 9786,
2015
Alexander, K., Pinter C., Andrea J., Fichtinger G., & Schreiner J. (2015).  3D Slicer Gel Dosimetry Analysis: Validation of the Calibration Process. World Congress on Medical Physics and Biomedical Engineering, June 7-12, 2015, Toronto, Canada. 51, 521-524.PDF icon Alexander2015.pdf (322.62 KB)
Schumacher, M., Lasso A., Cumming I., Rankin A., Falkson C., Schreiner J., et al. (2015).  3D-printed surface mould applicator for high-dose-rate brachytherapy. SPIE Medical Imaging 2015. 9415, PDF icon Schumacher2015-manuscript.pdf (739.76 KB)PDF icon Schumacher2015-poster.pdf (1.7 MB)
Clinkard, D., Moult E., Holden M., Davison C., Ungi T., Fichtinger G., et al. (2015).  Assessment of Lumbar Puncture Skill in Experts and Nonexperts Using Checklists and Quantitative Tracking of Needle Trajectories: Implications for Competency-Based Medical Education. Teaching and Learning in Medicine. 27, 51-56.
Ungi, T., Gauvin G., Lasso A., Yeo C. T., Rudan J., C. Engel J., et al. (2015).  Clinical Translation of Real Time Cautery Navigation for Breast Surgery. The Hamlyn Symposium on Medical Robotics. 19-20.PDF icon Ungi2015c.pdf (364.42 KB)
Andrea, J., Pinter C., & Fichtinger G. (2015).  Cloud computing of anatomical similarity. 13th Imaging Network Ontario Symposium (ImNO 2015). 35.PDF icon Andrea2015a.pdf (156.52 KB)File Andrea2015a-poster.pptx (864.04 KB)
Keri, Z., Sydor D., Ungi T., Holden M., McGraw R. C., Mousavi P., et al. (2015).  Computerized training system for ultrasound-guided lumbar puncture on abnormal spine models: a randomized controlled trial. Canadian Journal of Anesthesia. 62, 777-784.PDF icon Keri2015a.pdf (1.65 MB)
Alexander, K., Jechel C., Pinter C., Salomons G., Lasso A., Fichtinger G., et al. (2015).  Cross‐Validation of 3D Gamma Comparison Tools. AAPM. 42(6), 3385-3385.PDF icon Alexander2015_AAPM_Gamma.pdf (657.24 KB)
Carter, K., Lasso A., Ungi T., Morin E., & Fichtinger G. (2015).  Current sensing for navigated electrosurgery . 13th Imaging Network of Ontario Symposium (ImNO 2015). 37.File Carter2015b-slides.pptx (935.35 KB)File Carter2015b-poster.pptx (841.73 KB)PDF icon Carter2015b.pdf (148.88 KB)
Abou-Seido, N., Ungi T., Lasso A., McGraw R. C., & Fichtinger G. (2015).  Data Management Workflow And Architecture For Simulation-Based Medical Training. 29th International Congress and Exhibition of Computer Assisted Radiology Surgery. 10(Suppl 1), s78.PDF icon AbouSeido2015.pdf (251.59 KB)
Clinkard, D., Holden M., Ungi T., Messenger D., Fichtinger G., & McGraw R. C. (2015).  The Development and Validation of Hand Motion Analysis to Evaluate Competency in Central Line Catheterization. Academic Emergency Medicine. 22, 212-218.
Lougheed, M., Fichtinger G., & Ungi T. (2015).  Evaluation metrics for bone segmentation in ultrasound. SPIE Medical Imaging 2015. 9415,
Yeo, C. T., Davison C., Ungi T., Holden M., Fichtinger G., & McGraw R. C. (2015).  Examination of learning trajectories for simulated lumbar puncture training using hand motion analysis. Academic Emergency Medicine. 22, 1187-1195.
Vaughan, T., Lasso A., Ungi T., & Fichtinger G. (2015).  Hole filling with oriented sticks in ultrasound volume reconstruction. J. Med. Imag.. 2, PDF icon Vaughan2015_Manuscript.pdf (3.91 MB)

Pages